螺桿泵性能參數(shù)換算 | The Count of Characteristic Data of Pump Selected |
以下各章均列出產(chǎn)品性能表,當(dāng)用戶根據(jù)需要在性能表中無法查得軸功率及流量時(shí),可按如下方法近似確定: | When you can"t get the capacity power and capacity from the characteristic table you need count it: |
(一)軸功率的換算 | (一) The cowt of power |
1. 當(dāng)壓力由P變成P1而粘度、轉(zhuǎn)速不變時(shí),軸功率N:
N = (QP1/3.67η0)[1+(η0/η-1)P/P1] (Kw) 式中: Q、P均為性能表中列出的接近用戶需用要的那一組流量(m3/h)及壓力值(Mpa); η、η0為在性能表標(biāo)定的流量、壓力時(shí)對應(yīng)的總效率及容積效率。它們可在相應(yīng)的η-P曲線圖中查得。曲線均有離散性,按照"隨規(guī)格的增大而取大值" 的原則進(jìn)行取值。 |
1.When the pressure is from P to P1,but viscosity and speed do not change,you count the power N: N =(QP1/3.67η0)[1+(η0/η-1)P/P1] (Kw) Note: The Q, P is the data that you can get from characteristic table Q(m3/h) and P(Mpa). η,η0is the corresponding total efficiency and volume efficiency when the capacity and pressure is signed by Q, P. You can get them from η-P Drawing. |
2. 當(dāng)粘度從 E 變成 E1而壓力、轉(zhuǎn)速不變時(shí),
N = (QP/3.67η0)[1+(η0/η-1)√E1/E] (Kw) |
2. When the viscosity is from E to E1, but the pressure and speed don"t change, you can count the power: N = (QP/3.67η0)[1+(η0/η-1)√E1/E] (Kw) |
3. 轉(zhuǎn)速從 n 變成 n1時(shí),壓力、粘度不變時(shí),軸功率 N:
N = (Qpn/3.67η0n1)[1+(η0/η-1)√n1/n] (Kw) |
3. When the speed is from n to n1, but the pressure and viscosity don"t change, you can count the power N: N = (Qpn/3.67η0n1)[1+(η0/η-1)√n1/n] (Kw) |
(二) 流量的換算 |
(二) The count of capacity |
1. 對于粘度大于50E 的介質(zhì),當(dāng)粘度從E變成 E1時(shí),流量 Q 變?yōu)?Q1: Q1= Q/η0[1-(1-η0)1/K] (m3/h) K=(√E1+1.5)/(√E+1.5) 注:η0為標(biāo)定流量Q時(shí)的容積效率; E、E1單位恩氏粘度0E 。 |
1. When the Viscosity is from E1 and they are more than 50E, the capacity will be form Q to Q1: Q1= Q/η0[1-(1-η0)1/K] (m3/h) K=(√E1+1.5)/(√E+1.5) |
2. 當(dāng)轉(zhuǎn)速從n變成n1而粘度、壓力不變時(shí),流量Q1近似為: Q1= Q/η0[n1/n-(1-η0)] (m3/h) |
2.When the speed is from n to n1, but the viscosity and pressure don"t change, the capacity Q1can count approximately: Q1= Q/η0[n1/n-(1-η0)] (m3/h) |
冀公網(wǎng)安13098102000514號